Low Power Company, Inc. LP-4290 SPECpower_ssj2008 = Invalid overall ssj_ops/watt
Test Sponsor: Low Power Company, Inc. SPEC License #: 0 Test Method: Single Node
Tested By: Low Power Company, Inc. Test Location: Mountain View, CA Test Date: Apr 14, 2017
Hardware Availability: March 2017 Software Availability: Mar-2017 Publication: Unpublished
System Source: Low Power Company, Inc. System Designation: LP-4290-8H Power Provisioning: Line-powered
WARNING: PTDaemon 1.8.0-3505e615-20160120 is over 12 months old. Check http://www.spec.org/power/docs/SPECpower-Device_List.html to determine if a newer version is available. (see Run Rules Section 1.1)
WARNING: PTDaemon 1.8.0-3505e615-20160120 is over 12 months old. Check http://www.spec.org/power/docs/SPECpower-Device_List.html to determine if a newer version is available. (see Run Rules Section 1.1)
INVALID: Temperature Sensor "temp1" not accepted (see Run Rules Section 2.13.4)
WARNING: Autoranging was enabled for current on Power Analyzer "pwr1". The use of autoranging is discouraged. (see Run Rules Section 2.13.2)
WARNING: Autoranging was enabled for voltage on Power Analyzer "pwr1". The use of autoranging is discouraged. (see Run Rules Section 2.13.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 0, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 236 samples with unknown uncertainty out of 236 total samples (100.0%) in interval 1, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 235 samples with unknown uncertainty out of 235 total samples (100.0%) in interval 2, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 239 samples with unknown uncertainty out of 239 total samples (100.0%) in interval 3, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 238 samples with unknown uncertainty out of 238 total samples (100.0%) in interval 4, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 5, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 6, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 236 samples with unknown uncertainty out of 236 total samples (100.0%) in interval 7, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 235 samples with unknown uncertainty out of 235 total samples (100.0%) in interval 8, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 9, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 238 samples with unknown uncertainty out of 238 total samples (100.0%) in interval 10, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 11, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 12, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 13, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.7% 291,940 49.3 5,926
90% 89.7% 262,522 50.8 5,171
80% 79.6% 233,101 50.2 4,639
70% 70.0% 204,851 48.5 4,223
60% 60.4% 176,793 45.5 3,883
50% 49.8% 145,877 41.0 3,557
40% 40.0% 117,020 35.4 3,305
30% 30.3% 88,611 30.1 2,945
20% 20.0% 58,573 24.2 2,417
10% 10.1% 29,461 19.5 1,510
Active Idle 0 15.2 0
∑ssj_ops / ∑power = 3,926
Graph of results
System Under Test
Set: 'lp4290'
Set Identifier: lp4290
Set Description: System Under Test
# of Identical Nodes: 1
Comment: Here is a comment for this set.
Hardware
Hardware Vendor: Low Power Company, Inc.
Model: LP-4290
Form Factor: 1U
CPU Name: Intel Xeon E3-1260L v5
CPU Characteristics: Quad-Core, 2.9GHz, 8MB Intel Smart Cache(tm)
CPU Frequency (MHz): 2900
CPU(s) Enabled: 4 cores, 1 chip, 4 cores/chip
Hardware Threads: 8 (2 / core)
CPU(s) Orderable: 1 chips
Primary Cache: 128 KB I + 128 KB D on chip per core
Secondary Cache: 1 MB I+D on chip per chip
Tertiary Cache: 8 MB on chip per chip
Other Cache: None
Memory Amount (GB): 32
# and size of DIMM: 2 x 16 GB
Memory Details: 16GB 2133MHz DDR4 ECC; slots 2, and 4 populated
Power Supply Quantity and Rating (W): 1 x 110
Power Supply Details: Lopoco
Disk Drive: 4 x 120GB SSD
Disk Controller: Integrated SATA3 controller
# and type of Network Interface Cards (NICs) Installed: 2 x Gigabit Ethernet NIC
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 1000
Keyboard: USB/KVM
Mouse: USB/KVM
Monitor: Yes/KVM
Optical Drives: None
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): Ubuntu Server amd64
OS Version: 16.10
Filesystem: XFS
JVM Vendor: OpenJDK/JIT
JVM Version: openjdk-9-jre-headless 9~b134-2ubuntu1
JVM Command-line Options: -XrunFast -XconsumeLessPower
JVM Affinity: None
JVM Instances: 1
JVM Initial Heap (MB): Dynamic
JVM Maximum Heap (MB): Dynamic
JVM Address Bits: 64
Boot Firmware Version: 2.0
Management Firmware Version: 1.35
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: None
Boot Firmware Settings
none
Management Firmware Settings
none
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Low Power Company
Model: LP-4255-2I
CPU Description: Intel Xeon E3-1265
Memory amount (GB): 16
Software
Operating System (OS): Linux
JVM Vendor: OpenJDK
JVM Version: 7u121-2.6.8-2~deb8u1
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Hioki
Model: 3334
Serial Number: 150526689
Connectivity: USB
Input Connection: Default
Metrology Institute: NIST
Accredited by: Hioki
Calibration Label: Unknown
Date of Calibration: Unknown
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.8.0-3505e615-20160120
Setup Description: Unknown
Temperature Sensor temp1
Hardware Vendor: Digi
Model: Watchport H/T Sensor
Driver Version: io_ti 3.16.0-4-amd64
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 5mm in front of SUT
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 49.3 21.2
90% 50.8 21.2
80% 50.2 21.2
70% 48.5 21.2
60% 45.5 21.2
50% 41.0 21.2
40% 35.4 21.2
30% 30.1 21.2
20% 24.2 21.2
10% 19.5 21.2
Active Idle 15.2 21.2
Line Standard Minimum Temperature (°C) Elevation (m)
120V / 60 Hz / 1 phase / 2 wires 21.2 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     294,221
Calibration 2     292,409
Calibration 3     293,174
ssj_ops@calibrated=292,792
100% 99.7% 292,792 291,940
90% 89.7% 263,512 262,522
80% 79.6% 234,233 233,101
70% 70.0% 204,954 204,851
60% 60.4% 175,675 176,793
50% 49.8% 146,396 145,877
40% 40.0% 117,117 117,020
30% 30.3% 87,837 88,611
20% 20.0% 58,558 58,573
10% 10.1% 29,279 29,461
Active Idle   0 0
Graph of results