Low Power Company, Inc. LP-4290 SPECpower_ssj2008 = Invalid overall ssj_ops/watt
Test Sponsor: Low Power Company, Inc. SPEC License #: 0 Test Method: Single Node
Tested By: Low Power Company, Inc. Test Location: Mountain View, CA Test Date: Apr 18, 2017
Hardware Availability: March 2017 Software Availability: Mar-2017 Publication: Unpublished
System Source: Low Power Company, Inc. System Designation: LP-4290-8H Power Provisioning: Line-powered
WARNING: PTDaemon 1.8.0-3505e615-20160120 is over 12 months old. Check http://www.spec.org/power/docs/SPECpower-Device_List.html to determine if a newer version is available. (see Run Rules Section 1.1)
WARNING: PTDaemon 1.8.0-3505e615-20160120 is over 12 months old. Check http://www.spec.org/power/docs/SPECpower-Device_List.html to determine if a newer version is available. (see Run Rules Section 1.1)
WARNING: Autoranging was enabled for current on Power Analyzer "pwr1". The use of autoranging is discouraged. (see Run Rules Section 2.13.2)
WARNING: Autoranging was enabled for voltage on Power Analyzer "pwr1". The use of autoranging is discouraged. (see Run Rules Section 2.13.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 0, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 236 samples with unknown uncertainty out of 236 total samples (100.0%) in interval 1, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 236 samples with unknown uncertainty out of 236 total samples (100.0%) in interval 2, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 239 samples with unknown uncertainty out of 239 total samples (100.0%) in interval 3, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 239 samples with unknown uncertainty out of 239 total samples (100.0%) in interval 4, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 238 samples with unknown uncertainty out of 238 total samples (100.0%) in interval 5, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 6, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 7, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 235 samples with unknown uncertainty out of 235 total samples (100.0%) in interval 8, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 239 samples with unknown uncertainty out of 239 total samples (100.0%) in interval 9, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 10, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 238 samples with unknown uncertainty out of 238 total samples (100.0%) in interval 11, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 238 samples with unknown uncertainty out of 238 total samples (100.0%) in interval 12, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had 237 samples with unknown uncertainty out of 237 total samples (100.0%) in interval 13, exceeding the threshold of 1.0%. (see Run Rules Section 2.5.2)
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.7% 293,810 49.3 5,958
90% 89.5% 263,531 50.8 5,192
80% 79.7% 234,762 50.3 4,669
70% 69.6% 205,028 48.3 4,243
60% 59.4% 174,963 45.3 3,862
50% 50.0% 147,431 41.1 3,590
40% 40.0% 117,731 35.7 3,293
30% 29.6% 87,298 29.6 2,944
20% 19.9% 58,621 23.8 2,458
10% 10.0% 29,538 19.5 1,513
Active Idle 0 15.4 0
∑ssj_ops / ∑power = 3,941
Graph of results
System Under Test
Set: 'lp4290'
Set Identifier: lp4290
Set Description: System Under Test
# of Identical Nodes: 1
Comment: Here is a comment for this set.
Hardware
Hardware Vendor: Low Power Company, Inc.
Model: LP-4290
Form Factor: 1U
CPU Name: Intel Xeon E3-1260L v5
CPU Characteristics: Quad-Core, 2.9GHz, 8MB Intel Smart Cache(tm)
CPU Frequency (MHz): 2900
CPU(s) Enabled: 4 cores, 1 chip, 4 cores/chip
Hardware Threads: 8 (2 / core)
CPU(s) Orderable: 1 chips
Primary Cache: 128 KB I + 128 KB D on chip per core
Secondary Cache: 1 MB I+D on chip per chip
Tertiary Cache: 8 MB on chip per chip
Other Cache: None
Memory Amount (GB): 32
# and size of DIMM: 2 x 16 GB
Memory Details: 32GB 2133MHz DDR4 ECC; slots 2 and 4 populated
Power Supply Quantity and Rating (W): 1 x 110
Power Supply Details: Lopoco
Disk Drive: 4 x 120GB SSD
Disk Controller: Integrated SATA3 controller
# and type of Network Interface Cards (NICs) Installed: 2 x Gigabit Ethernet NIC
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 1000
Keyboard: USB/KVM
Mouse: USB/KVM
Monitor: Yes/KVM
Optical Drives: None
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): Ubuntu Server amd64
OS Version: 16.10
Filesystem: XFS
JVM Vendor: OpenJDK/JIT
JVM Version: openjdk-9-jre-headless 9~b134-2ubuntu1
JVM Command-line Options: -XrunFast -XconsumeLessPower
JVM Affinity: None
JVM Instances: 1
JVM Initial Heap (MB): Dynamic
JVM Maximum Heap (MB): Dynamic
JVM Address Bits: 64
Boot Firmware Version: 2.0
Management Firmware Version: 1.35
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: None
Boot Firmware Settings
none
Management Firmware Settings
none
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Low Power Company
Model: LP-4255-2I
CPU Description: Intel Xeon E3-1265
Memory amount (GB): 16
Software
Operating System (OS): Linux
JVM Vendor: OpenJDK
JVM Version: 7u121-2.6.8-2~deb8u1
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Hioki
Model: 3334
Serial Number: 150526689
Connectivity: USB
Input Connection: Default
Metrology Institute: NIST
Accredited by: Hioki
Calibration Label: Unknown
Date of Calibration: Unknown
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.8.0-3505e615-20160120
Setup Description: Unknown
Temperature Sensor temp1
Hardware Vendor: Digi
Model: Watchport H/T Sensor
Driver Version: io_ti 3.16.0-4-amd64
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 5mm in front of SUT
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 49.3 22.4
90% 50.8 22.4
80% 50.3 22.4
70% 48.3 22.5
60% 45.3 22.5
50% 41.1 22.6
40% 35.7 22.6
30% 29.6 22.6
20% 23.8 22.6
10% 19.5 22.7
Active Idle 15.4 22.7
Line Standard Minimum Temperature (°C) Elevation (m)
120V / 60 Hz / 1 phase / 2 wires 22.4 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     295,907
Calibration 2     294,148
Calibration 3     295,077
ssj_ops@calibrated=294,612
100% 99.7% 294,612 293,810
90% 89.5% 265,151 263,531
80% 79.7% 235,690 234,762
70% 69.6% 206,229 205,028
60% 59.4% 176,767 174,963
50% 50.0% 147,306 147,431
40% 40.0% 117,845 117,731
30% 29.6% 88,384 87,298
20% 19.9% 58,922 58,621
10% 10.0% 29,461 29,538
Active Idle   0 0