Low Power Company, Inc. LP-4290 SPECpower_ssj2008 = Invalid overall ssj_ops/watt
Test Sponsor: Low Power Company, Inc. SPEC License #: 4777 Test Method: Single Node
Tested By: Low Power Company, Inc. Test Location: Mountain View, CA Test Date: Apr 19, 2017
Hardware Availability: March 2017 Software Availability: Mar-2017 Publication: Unpublished
System Source: Low Power Company, Inc. System Designation: LP-4290-8H Power Provisioning: Line-powered
WARNING: PTDaemon 1.8.0-3505e615-20160120 is over 12 months old. Check http://www.spec.org/power/docs/SPECpower-Device_List.html to determine if a newer version is available. (see Run Rules Section 1.1)
WARNING: PTDaemon 1.8.0-3505e615-20160120 is over 12 months old. Check http://www.spec.org/power/docs/SPECpower-Device_List.html to determine if a newer version is available. (see Run Rules Section 1.1)
INVALID: Power Analyzer "pwr1" had 234 samples with uncertainty exceeding 1.0% out of 237 total samples (98.7%) in interval 12, exceeding the threshold of 5.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had an average uncertainty of 1.1% in interval 12, exceeding the threshold of 1.0%. (see Run Rules Section 2.13.2)
INVALID: Power Analyzer "pwr1" had 237 samples with uncertainty exceeding 1.0% out of 237 total samples (100.0%) in interval 13, exceeding the threshold of 5.0%. (see Run Rules Section 2.5.2)
INVALID: Power Analyzer "pwr1" had an average uncertainty of 1.3% in interval 13, exceeding the threshold of 1.0%. (see Run Rules Section 2.13.2)
Benchmark Results Summary
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
Calibration 1 46.6 22.8
Calibration 2 47.1 22.9
Calibration 3 47.3 22.9
100% 47.2 23.0
90% 48.8 23.1
80% 48.4 23.1
70% 46.3 23.1
60% 43.6 23.2
50% 39.2 23.2
40% 33.9 23.3
30% 27.8 23.4
20% 22.4 23.4
10% 17.8 23.4
Active Idle 13.6 23.5
Graph of power and temperature
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Hioki
Model: 3334
Serial Number: 150526689
Connectivity: USB
Input Connection: Default
Metrology Institute: NIST
Accredited by: Hioki
Calibration Label: N-3650
Date of Calibration: 8-Jun-2009
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.8.0-3505e615-20160120
Setup Description: Unknown
Temperature Sensor temp1
Hardware Vendor: Digi
Model: Watchport H/T Sensor
Driver Version: io_ti 3.16.0-4-amd64
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 5mm in front of SUT
Notes
None
Power Details for Device pwr1
Target Load Voltage (V) Current (A) Avg Power Factor Avg Active Power (W) Power Measurement Uncertainty (%)
Avg Range Avg Range
Calibration 1 120 150.0 0.397 1.0 0.982 46.6 0.5%
Calibration 2 120 150.0 0.400 1.0 0.982 47.1 0.5%
Calibration 3 120 150.0 0.401 1.0 0.982 47.3 0.5%
100% 120 150.0 0.400 1.0 0.982 47.2 0.5%
90% 120 150.0 0.417 1.0 0.973 48.8 0.5%
80% 120 150.0 0.420 1.0 0.962 48.4 0.5%
70% 120 150.0 0.409 1.0 0.947 46.3 0.5%
60% 119 150.0 0.393 1.0 0.932 43.6 0.5%
50% 119 150.0 0.359 1.0 0.916 39.2 0.6%
40% 120 150.0 0.316 1.0 0.900 33.9 0.7%
30% 120 150.0 0.262 1.0 0.885 27.8 0.8%
20% 120 150.0 0.214 1.0 0.876 22.4 0.9%
10% 120 150.0 0.170 1.0 0.873 17.8 1.1%
Active Idle 120 150.0 0.128 1.0 0.886 13.6 1.3%
Power details for pwr1