Low Power Company, Inc. Lopoco LP-4290 Series Server SPECpower_ssj2008 = 6,082 overall ssj_ops/watt
Test Sponsor: Low Power Company, Inc. SPEC License #: 4777 Test Method: Single Node
Tested By: Low Power Company, Inc. Test Location: Mountain View, CA Test Date: May 8, 2017
Hardware Availability: January 2017 Software Availability: Jan-2017 Publication: Unpublished
System Source: Low Power Company, Inc. System Designation: LP-4290-2I Power Provisioning: Line-powered
WARNING: PTDaemon 1.8.0-3505e615-20160120 is over 12 months old. Check http://www.spec.org/power/docs/SPECpower-Device_List.html to determine if a newer version is available. (see Run Rules Section 1.1)
WARNING: PTDaemon 1.8.0-3505e615-20160120 is over 12 months old. Check http://www.spec.org/power/docs/SPECpower-Device_List.html to determine if a newer version is available. (see Run Rules Section 1.1)
WARNING: Power Analyzer "pwr1" had 3 samples with uncertainty exceeding 1.0% out of 238 total samples (1.3%) in interval 10.
Benchmark Results Summary
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
Calibration 1 43.7 25.6
Calibration 2 44.2 25.7
Calibration 3 44.2 25.8
100% 44.2 25.8
90% 40.6 25.9
80% 37.3 25.9
70% 34.4 25.9
60% 31.0 26.0
50% 28.2 26.0
40% 25.1 26.1
30% 21.9 26.1
20% 18.4 26.2
10% 14.8 26.2
Active Idle 10.7 26.2
Graph of power and temperature
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Hioki
Model: 3334
Serial Number: 150526689
Connectivity: USB
Input Connection: Default
Metrology Institute: NIST
Accredited by: Hioki
Calibration Label: N-3650
Date of Calibration: 8-Jun-2009
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.8.0-3505e615-20160120
Setup Description: Connected to SUT PSU
Temperature Sensor temp1
Hardware Vendor: Digi
Model: Watchport H/T Sensor
Driver Version: io_ti 3.16.0-4-amd64
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 5mm in front of SUT
Notes
Power Details for Device pwr1
Target Load Voltage (V) Current (A) Avg Power Factor Avg Active Power (W) Power Measurement Uncertainty (%)
Avg Range Avg Range
Calibration 1 119 150.0 0.374 1.0 0.981 43.7 0.5%
Calibration 2 119 150.0 0.378 1.0 0.981 44.2 0.5%
Calibration 3 119 150.0 0.377 1.0 0.981 44.2 0.5%
100% 119 150.0 0.378 1.0 0.981 44.2 0.5%
90% 120 150.0 0.349 1.0 0.973 40.6 0.5%
80% 120 150.0 0.324 1.0 0.963 37.3 0.6%
70% 120 150.0 0.302 1.0 0.952 34.4 0.6%
60% 120 150.0 0.276 1.0 0.939 31.0 0.7%
50% 120 150.0 0.255 1.0 0.926 28.2 0.7%
40% 120 150.0 0.230 1.0 0.911 25.1 0.8%
30% 120 150.0 0.204 1.0 0.893 21.9 0.9%
20% 120 150.0 0.176 0.3 0.872 18.4 0.5%
10% 120 150.0 0.145 0.3 0.853 14.8 0.5%
Active Idle 120 150.0 0.106 0.3 0.846 10.7 0.7%
Power details for pwr1