X-MimeOLE: Produced By Microsoft Exchange V6.5
Received: by onstor-exch02.onstor.net 
	id <01C85BEB.653BE3C0@onstor-exch02.onstor.net>; Sun, 20 Jan 2008 22:06:35 -0700
MIME-Version: 1.0
Content-Type: multipart/alternative;
	boundary="----_=_NextPart_001_01C85BEB.653BE3C0"
Content-class: urn:content-classes:message
Subject: RE: Is there a way
Date: Sun, 20 Jan 2008 22:06:34 -0700
Message-ID: <BB375AF679D4A34E9CA8DFA650E2B04E07BC050B@onstor-exch02.onstor.net>
In-Reply-To: <BB375AF679D4A34E9CA8DFA650E2B04E07BC045E@onstor-exch02.onstor.net>
X-MS-Has-Attach: 
X-MS-TNEF-Correlator: 
Thread-Topic: Is there a way
Thread-Index: AchaU8IIoxq4e6hUSOS8Xuu7Yh/7NwAj6ICQAEF+WCA=
References: <BB375AF679D4A34E9CA8DFA650E2B04E056C92E3@onstor-exch02.onstor.net> <BB375AF679D4A34E9CA8DFA650E2B04E07BC045E@onstor-exch02.onstor.net>
From: "Brian Stark" <brian.stark@onstor.com>
To: "Joshua Goldenhar" <joshua.goldenhar@onstor.com>,
	"Larry Scheer" <larry.scheer@onstor.com>
Cc: "dl-Cougar" <dl-Cougar@onstor.com>

This is a multi-part message in MIME format.

------_=_NextPart_001_01C85BEB.653BE3C0
Content-Type: text/plain;
	charset="us-ascii"
Content-Transfer-Encoding: quoted-printable

There's no way to send a signal to the 'controlling' FPGA on the board
from outside the box to force a reboot of the board.  Plus, the only
resources that this FPGA controls are the frontpanel LEDs. =20

If the SSC detects a processor is down, then it can force a reboot of
the whole board.  There's also watchdog protection on the SSC, which
will reboot the whole board if needed. =20


Brian


> _____________________________________________=20
> From: 	Joshua Goldenhar =20
> Sent:	Saturday, January 19, 2008 1:38 PM
> To:	Larry Scheer; Brian Stark
> Cc:	dl-Cougar
> Subject:	RE: Is there a way
>=20
> Yuck.
>=20
> Can't we send a reset to the controlling FPGA of one board and do a
> soft/hard reset?
>=20
> -Josh
>=20
> Josh Goldenhar
> Phone: 408 963 2408, Cell: 408 547 7693
>=20
> _____________________________________________
> From: Larry Scheer=20
> Sent: Friday, January 18, 2008 8:29 PM
> To: Brian Stark
> Cc: dl-Cougar
> Subject: Is there a way
>=20
> Brian,
>     With the 6720s (Cluster-in-a-box) is there a way to power off just
> one of the mother boards?
>=20
> When we get remote power set up on these chassis if we ever use the
> power off command we will be shutting off both NAS Gateways.=20
>=20
> What do we do when only one gateway is wedged and we  need to power
> cycle it to recover?=20
>=20
> This doesn't happen often but occasionally a power cycle is the only
> way to get a system "un-stuck." =20
>=20
> Larry

------_=_NextPart_001_01C85BEB.653BE3C0
Content-Type: text/html;
	charset="us-ascii"
Content-Transfer-Encoding: quoted-printable

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 3.2//EN">
<HTML>
<HEAD>
<META HTTP-EQUIV=3D"Content-Type" CONTENT=3D"text/html; =
charset=3Dus-ascii">
<META NAME=3D"Generator" CONTENT=3D"MS Exchange Server version =
6.5.7653.38">
<TITLE>RE: Is there a way</TITLE>
</HEAD>
<BODY>
<!-- Converted from text/rtf format -->

<P><FONT COLOR=3D"#0000FF" SIZE=3D2 FACE=3D"Arial">There's no way to =
send a signal to the 'controlling' FPGA on the board from outside the =
box to force a reboot of the board.&nbsp; Plus, the only resources that =
this FPGA controls are the frontpanel LEDs.&nbsp; </FONT></P>

<P><FONT COLOR=3D"#0000FF" SIZE=3D2 FACE=3D"Arial">If the SSC detects a =
processor is down, then it can force a reboot of the whole board.&nbsp; =
There's also watchdog protection on the SSC, which will reboot the whole =
board if needed.&nbsp; </FONT></P>
<BR>

<P><FONT COLOR=3D"#0000FF" SIZE=3D2 FACE=3D"Arial">Brian</FONT>
</P>
<BR>
<UL>
<P><FONT SIZE=3D1 =
FACE=3D"Tahoma">_____________________________________________ </FONT>

<BR><B><FONT SIZE=3D1 FACE=3D"Tahoma">From: &nbsp;</FONT></B> <FONT =
SIZE=3D1 FACE=3D"Tahoma">Joshua Goldenhar&nbsp; </FONT>

<BR><B><FONT SIZE=3D1 FACE=3D"Tahoma">Sent:&nbsp;&nbsp;</FONT></B> <FONT =
SIZE=3D1 FACE=3D"Tahoma">Saturday, January 19, 2008 1:38 PM</FONT>

<BR><B><FONT SIZE=3D1 =
FACE=3D"Tahoma">To:&nbsp;&nbsp;&nbsp;&nbsp;</FONT></B> <FONT SIZE=3D1 =
FACE=3D"Tahoma">Larry Scheer; Brian Stark</FONT>

<BR><B><FONT SIZE=3D1 =
FACE=3D"Tahoma">Cc:&nbsp;&nbsp;&nbsp;&nbsp;</FONT></B> <FONT SIZE=3D1 =
FACE=3D"Tahoma">dl-Cougar</FONT>

<BR><B><FONT SIZE=3D1 =
FACE=3D"Tahoma">Subject:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</FONT>=
</B> <FONT SIZE=3D1 FACE=3D"Tahoma">RE: Is there a way</FONT>
</P>

<P><FONT COLOR=3D"#000080" SIZE=3D2 FACE=3D"Arial">Yuck.</FONT>
</P>

<P><FONT COLOR=3D"#000080" SIZE=3D2 FACE=3D"Arial">Can&#8217;t we send a =
reset to the controlling FPGA of one board and do a soft/hard =
reset?</FONT>
</P>

<P><FONT COLOR=3D"#000080" SIZE=3D2 FACE=3D"Arial">-Josh</FONT>
</P>

<P><FONT COLOR=3D"#000080" SIZE=3D2 FACE=3D"Arial">Josh Goldenhar</FONT>

<BR><FONT COLOR=3D"#000080" SIZE=3D2 FACE=3D"Arial">Phone: 408 963 2408, =
Cell: 408 547 7693</FONT>
</P>

<P><FONT SIZE=3D2 =
FACE=3D"Tahoma">_____________________________________________<BR>
</FONT><B><FONT SIZE=3D2 FACE=3D"Tahoma">From:</FONT></B><FONT SIZE=3D2 =
FACE=3D"Tahoma"> Larry Scheer<BR>
</FONT><B><FONT SIZE=3D2 FACE=3D"Tahoma">Sent:</FONT></B><FONT SIZE=3D2 =
FACE=3D"Tahoma"> Friday, January 18, 2008 8:29 PM<BR>
</FONT><B><FONT SIZE=3D2 FACE=3D"Tahoma">To:</FONT></B><FONT SIZE=3D2 =
FACE=3D"Tahoma"> Brian Stark<BR>
</FONT><B><FONT SIZE=3D2 FACE=3D"Tahoma">Cc:</FONT></B><FONT SIZE=3D2 =
FACE=3D"Tahoma"> dl-Cougar<BR>
</FONT><B><FONT SIZE=3D2 FACE=3D"Tahoma">Subject:</FONT></B><FONT =
SIZE=3D2 FACE=3D"Tahoma"> Is there a way</FONT>
</P>

<P><FONT SIZE=3D2 FACE=3D"Arial">Brian,</FONT>

<BR><FONT SIZE=3D2 FACE=3D"Arial">&nbsp;&nbsp;&nbsp; With the 6720s =
(Cluster-in-a-box) is there a way to power off just one of the mother =
boards?</FONT>
</P>

<P><FONT SIZE=3D2 FACE=3D"Arial">When we get remote power set up on =
these chassis if we ever use the power off command we will be shutting =
off both NAS Gateways. </FONT></P>

<P><FONT SIZE=3D2 FACE=3D"Arial">What do we do when only one gateway is =
wedged and we&nbsp; need to power cycle it to recover? </FONT>
</P>

<P><FONT SIZE=3D2 FACE=3D"Arial">This doesn&#8217;t happen often but =
occasionally a power cycle is the only way to get a system =
&#8220;un-stuck.&#8221;&nbsp; </FONT>
</P>

<P><FONT SIZE=3D2 FACE=3D"Arial">Larry</FONT>
</P>
</UL>
</BODY>
</HTML>
------_=_NextPart_001_01C85BEB.653BE3C0--